[摘要] 我市工程桩验收时往往采用高应变动力检测进行抽检,而高应变检测是要建立在大量的静载荷试验基础上进行对比总结,以提高基桩高应变动力检测的精度。我们在近几年的工程中,对该方法进行了分析汇总及研究,并在实际工程中推广应用,取得了良好的效果。本文仅列举其中的4枚试桩动静比对资料来反应其高应变检测效果。
[关键词] 基桩, 静载试验 ,高应变CASE,曲线拟合法
[abstract] the our city when acceptance of engineering piles often using high strain dynamic testing sampling inspection, and high strain detection is to be built on a lot of static load test are summarized based on the contrast, in order to improve the foundation pile high strain dynamic testing precision. We in the engineering, the method of the aggregation and analysis, and the real project application and achieved good effect. This paper only lists one of the four other than static pile test data to its high strain detection effect reaction.
[key words] the foundation pile, the static load test, high strain CASE, curve-fitting
在工程桩检测中高应变动力检测以其具有的简便、快捷、经济等优点,越来越多地在工程中应用,但无论是行业标准还是地方规定均要求在可靠的动静对比分析资料基础上进行。我公司在工程检测中时常进行高应变与静载荷试验的动静比对分析,现列举其中4枚试桩进行动静对比分析和总结,完善检测方法,提高基桩检测水平。
http:///
一、试桩简介
本试桩工程在中山市东区略靠近张家边的一个工地,场地岩土层依次为杂填土(0.8~1.0m)、粘土(2.1~2.5m)淤泥质粉质粘土(16.2~18.5m)、粘土(5.0~
8.7m)、粉砂(1.0~1.4m)、粉质粘土(6.8~10.7m)、含粘性土角砾(0.8~1.2m)、含砾粉质粘土(3.2~4.9m)、强风化熔结凝灰岩(1.5~2.1m),中风化熔结凝灰岩(3.5~4.7m)、微风化熔结凝灰岩,桩端均进入中风化熔结凝灰岩。各试桩概况如下表1。