酸化-好氧-混凝组合工艺处理印染废水的工程实践
酸化-好氧-混凝组合工艺处理印染废水的工程实践
摘要:针对某集中式印染废水处理厂的进水水质、水量的特点,采用酸化-好氧-混凝组合工艺进行处理。实践证明,采用调节-前混凝-好氧-后混凝工艺处理印染废水也是可行的。在进水COD为1000mg/L以下,色度为256倍时,出水COD 低于100mg/L,色度低于40倍,即各项出水水质指标符合《GB8978-96 污水排放综合标准》中的一级排放标准。
关键词:印染废水;酸化调节;活性污泥;混凝
Abstract: in a centralized printing and dyeing wastewater treatment plants fill the water quality and quantity, character and the acidification-good oxygen-coagulation combination process for processing. Practice shows that the regulation-former coagulation-good oxygen-coagulation process after printing and dyeing wastewater is feasible. In the water for 1000 mg/L COD below, chroma for 256 times, water below 100 mg/L COD, chroma less than 40 times, namely the effluent water quality index comply with the GB8978-96 integrated wastewater discharge standard, the level of discharging standard.
Keywords: printing and dyeing wastewater; Acidification regulation; Activated sludge; coagulation
1引言
据统计,全国印染废水处理设施总投资超过百亿元人民币[1],产生的污水量较大,水质复杂,选择合适的污水处理工艺是十分必要的。本文主要就是探讨酸化-好氧-混凝工艺在集中式印染废水处理厂的启动和运行,使污水处理厂正常稳定运行,实现经济效益和环境效益。
南方某污水处理厂共收集园区内36家印染企业排放的污水,在36家企业中,规模最大的日排水量为3000m3,规模最少的仅有400m3/d,其中大多数印染企业的排水量1000m3/d左右。根据对园区内各企业生产规模、生产工艺及生产产品的详细调查分析,确定园区污水处理厂工程规模为30000m3/d。
2处理工艺
2.1进水水质
根据园区各企业实际情况,经调查分析,确定园区污水厂主要进水水质见表1。其它未规定的污染物指标均以《污水排入城市下水道水质标准》(CJ3082-1999)为准。
2.2出水水质