安钢75t/h干熄焦装置的技术改进
张 渊 李剑利 张素芬 曹 文 张为斌 孙玉红
(安阳钢铁股份有限公司焦化厂,安阳 455004)
摘 要 介绍安钢75t/h干熄焦生产现状,分析炉顶水封槽漏水、高温膨胀节烧穿、干熄焦系统风量调节砖的均衡调节等设备故障产生的原因及改进措施,为进一步优化系统运行提供参考资料,对干熄焦生产维护和检修工作有一定的借鉴意义。
关键词 干熄焦水封槽 风量调节砖 膨胀节 工艺改进
Anyang Iron and Steel 75t/h was
Amended into the CDQ Device
Zhang Yuan Li Jianli Zhang Sufen Cao Wen Zhang Weibin SunYuhong
(Anyang Iron and Steel Coking Plant shares of the Company,Anyang, 455004)
Abstract An steel 75t/h CDQ production status of water seal tank leaking roof, high temperature expansion joints burn, CDQ air volume control system regulating the balance of brick and other causes of equipment failure and improvement measures to further optimize provide reference information system operation, maintenance and repair of production CDQ some reference work.
Key words CDQ water seal tank, air volume control brick, expansion joint, process improvement
安钢焦化厂75t/h干熄焦2009年7月投产以来,在环保、节能、改善焦炭质量和降低冶炼焦成本等方面发挥了积极的作用。但在运行中相继出现了炉顶水封槽漏水、一次除尘膨胀节烧穿泄漏、风量分配不均匀造成排焦温度偏高等问题。依靠日常维护,干熄焦系统已无法正常生产,于2010年11月停产大修使上述问题得到了解决,年修后通过不断优化工艺参数和控制系统,确保了干熄焦系统持续稳定、高效和安全运行。
1 运行中存在的问题
1.1 炉顶水封槽
干熄炉水封槽位于干熄炉顶部,主要由水封槽本体、上水管道、压缩空气管道、内侧隔热板及附属密封材料及回水管道等组成。由于水封槽本体内圈直接与炉内循环气体接触,温度较高,所以选用不锈钢材质。
2010年3月19日、7月17日、9月14日、11月20日,干熄炉先后四次发生水封槽内圈根部焊缝开焊漏水事故。由于干熄炉水封漏水与红焦发生水煤气反应,造成循环气体中H2和CO含量急剧上升,易发生爆炸事故,同时漏水形成的的侵蚀和温度骤变对砌体耐材造成严重损坏。 张渊,男,硕士研究生,高级工程师,从事煤化工方向,caowen1976@126.com 1176
安钢75th干熄焦装置的技术改进.doc下载久久建筑网m.kkreddy.com提供大量:建筑图纸、施工方案、工程书籍、建筑论文、合同表格、标准规范、CAD图纸等内容。